intermittent

FSR pressure treated cedar is tested in accordance to the following standards:

UL 790, UlC-S-107-M, ASTM-E-108, UBC-15-2, NFP A256

ICC ESR 1410, CSFM Listing #4150-1735-101

ICC ESR 2867, CSFM Listing #4150-1735-100

Download the Material Safety Data Sheet here.whitespace

certifications_logos

Testing Criteria:

Flying Brand Test:
Class Flame Temperature Flame Application
A 1400 ± 50° F 10 Minutes
B 1400 ± 50° F 10 Minutes
C 1400 ± 50° F 4 Minutes
Spread-of-Flame Test:
Class Flame Temperature Flame Application
A 1400 ± 50° F 10 Minutes
B 1400 ± 50° F 10 Minutes
C 1400 ± 50° F 4 Minutes
Intermittent-Flame Test:
Class Flame Temperature Flame On Minutes Flame Off Minutes Number of Test Cycles
A 1400 ± 50° F 2 2 15
B 1400 ± 50° F 2 2 8
C 1400 ± 50° F 1 2 3
Burning Brand Test:
Class Brand Size Brand Wood No. of Brands
A 12″ x 12″, 2.25″ thick Douglas Fir 1
B 6″ x 6″, 2.25″ thick Douglas Fir 2
C 1.5″ x 1.5″, .78125″ thick White Pine 20
Rain Test:
Class Exposure
A, B, and C Twelve one week conditioning cycles of 96 hours of water exposure at a rate of 0.7″ of water per hour, followed by 72 hours of drying time at 140° F. This equates to 20 to 30 years of actual outdoor rain and wear.
Weathering Test:
Class Exposure
A, B, and C All products have passed the accelerated weathering test. Optional Treatments are available that have passed the California State Fire Marshall & ICC 10 year, natural weather test